FAS4000 vector inverters

FAS4000 vector frequency inverter with motion controller. In the power range from 0.37 to 3.0 kW. Perfect for controlling 3-phase asynchronous electric motors with incremental encoders. Archival product available via the website.

Vector Inverters FAS4000 Stober

  • Three control modes: U/f control from 0 to 400Hz, vector control from 0 to 100Hz, vector control with encoder
  • Three types of control: Speed, position, torque, and current control
  • Two types of position control: Block positioning and command positioning
  • Serial communication: RS232 compatible with USS protocol
  • Compatible with incremental HTL encoders
  • Integrated I/O: 5 digital inputs / 2 digital outputs, 1 analog input, 1x enable
  • Free software: FDS-Tool for programming, diagnostics, and application parameter storage
  • Paramodul: Exchangeable memory for application parameters
  • Integrated motor thermal protection: Motor temperature sensor input
  • Integrated chopper: Compatible with braking resistor
  • Steel housing
  • Protection class: IP20
  • Motor selection from a predefined parameter list (no need for manual adjustment)
  • Motor control for both delta and star connection
  • Extended constant torque characteristic up to 87Hz when using delta connection
  • Up to 7 predefined set values can be programmed
  • Direct brake control on the motor
  • EMC plate: For mounting the shield of power and encoder cables
  • Recommended: Use shielded power and encoder cables with grounding on both ends

Table of FAS4000 Stober vector inverters

Typ: Rated power Rated current Supply voltage Substitute
FAS4008 0,37 kW 3×2,1 A 1×230 VAC
FAS4016 0,75 kW 3×4,0 A 1×230 VAC FDS5007
FAS4009 0,37 kW 3×1,3 A 3×400 VAC FDS5004
FAS4014 0,75 kW 3×2,1 A 3×400 VAC FDS5008
FAS4020 1,10 kW 3×2,9 A 3×400 VAC
FAS4028 1,50 kW 3×4,0 A 3×400 VAC FDS5015
FAS4038 2,20 kW 3×5,5 A 3×400 VAC FDS5022
FAS4050 3,00 kW 3×7,0 A 3×400 VAC FDS5040

Optional Equipment for FAS4000 Vector Inverters:

  • POSI-Upgrade: Enables positioning (position control) by extending the inverter’s functionality with accuracy up to a single encoder increment.
  • Kommubox: Communication via Profibus-DP and CANopen.
  • Controlbox: External programmer with a display and keypad, external memory for application parameters for up to 7 inverters, and an integrated manual operation function.
  • PC-FDS connection cable (ID no: 41488): For inverter programming.

Catalogues

441581_0004_IBAL_FAS_4000_en.pdf -FAS4000 vector inverter user manual in English